Titel: |
Titel:
Radon sensor networks for large buildings: balancing the trade-off between energy efficiency and health
|
Autoren: |
Autoren:
Röttger, Stefan, Physikalisch-Technische Bundesanstalt (PTB), Fachbereich 6.1, Radioaktivität, ORCID: 0000-0002-4750-9563Nötzel, Ralf, Universität Siegen, Siegen, GERMANY Honig, Anja, Physikalisch-Technische Bundesanstalt (PTB), Fachbereich 6.1, Radioaktivität, ORCID: 0009-0007-9744-9822 Sabot, Benoit, Université Paris-Saclay, CEA, List, Palaiseau, France, ORCID: 0000-0003-3043-8006 Weinberg, Kerstin, Universität Siegen, Siegen, GERMANY, ORCID: 0000-0002-2213-8401 |
Beitragende: |
Beitragende:
HostingInstitution: Physikalisch-Technische Bundesanstalt (PTB), ISNI: 0000 0001 2186 1887
|
Seiten: |
Seiten:
12
|
Sprachen: |
Sprachen:
en
|
DOI: |
DOI:
10.7795/120.20250711
|
Art der Ressource: |
Art der Ressource:
PTB: Zeitschriftenartikel,
DINI: Article,
DataCite: JournalArticle
|
Verlag: |
Verlag:
Physikalisch-Technische Bundesanstalt (PTB)
|
Rechte: |
Rechte:
https://creativecommons.org/licenses/by/4.0/CC BY 4.0 |
Beziehungen: |
Beziehungen:
IsIdenticalTo: DOI 10.1515/teme-2025-0036
|
Datumsangaben: |
Datumsangaben:
Verfügbar:
2025-07-11
|
Klassifikationen: |
Klassifikationen:
OCIS 120.0120 Instrumentation, measurement, and metrology ; PACS 23 Radioactivity
|
Datei: |
Datei:
Datei herunterladen
(application/pdf)
2.0 MB
MD5 Prüfsumme: f20c85a02a7ce7be3865eaaa67d3655b SHA256 Prüfsumme: e7065f327021d76e8c95675709b3aed692bf942fba811e84f1be68b89dfb1556 |
Stichwörter: |
Stichwörter:
Radon ;
low-level activity concentration ;
Radon- NET ;
pulse ionization chamber
|
Zusammenfassung: |
Zusammenfassung:
Radon 222 is a radioactive noble gas that is formed in the decay of the primordial 238U decay chain, with an average abundance of 3 parts per million (3 g ⋅ t-1) in the earth's crust. Since radon is the only noble gas in the decay chain, it has with its half live T12 = 3.8232(8) d, the ability to emanate from the ground or building materials and to interfere with the biosphere. Taking into account Directive 2013/59/Euratom, the EURAMET EPM project RadonNET was founded to find a trade-off between energy efficiency and health effects by means of measurements with small uncertainties. With this in mind, an pulse ionization chamber for the time-resolved measurement of radon activity at low concentrations is described here. The solution shown is characterized by low sensitivity to room and impact noise. Experimental investigations show the properties of the pulse ionization chamber under various conditions, particularly with regard to its use in sensor networks in larger buildings or future cities.
|
Zitat: |
Zitat:
Röttger, Stefan, Nötzel, Ralf, Honig, Anja, Sabot, Benoit and Weinberg, Kerstin. "Radon sensor networks for large buildings: balancing the trade-off between energy efficiency and health" tm - Technisches Messen, 2025. https://doi.org/10.1515/teme-2025-0036
|
Förderung: |
Förderung:
European Commission (EC), ISNI: 0000 0001 2162 673X, Grant Title: Radon metrology: Sensor networks for large buildings and future cities, Grant Number: 23IND07 RadonNET
|