Titel: |
Titel:
Production of radioactive traceable reference materials for measuring radioactive pollutants in the environment
|
Autoren: |
Autoren:
Chambon, Lucille, Commissariat à l'énergie atomique et aux énergies alternatives, Paris, FRANCE, ORCID: 0000-0002-6034-5233Gupta, Soumya, Commissariat à l'énergie atomique et aux énergies alternatives, Paris, FRANCE Isnard, Hélène, Commissariat à l'énergie atomique et aux énergies alternatives, Paris, FRANCE Pierre, S., Commissariat à l'énergie atomique et aux énergies alternatives, Paris, FRANCE Sabot, B., Commissariat à l'énergie atomique et aux énergies alternatives, Paris, FRANCE Alle Autoren anzeigen (19) |
Beitragende: |
Beitragende:
HostingInstitution: Physikalisch-Technische Bundesanstalt (PTB), ISNI: 0000 0001 2186 1887
|
Seiten: |
Seiten:
15
|
Sprachen: |
Sprachen:
en
|
DOI: |
DOI:
10.7795/810.20251001B
|
Art der Ressource: |
Art der Ressource:
PTB: Konferenzartikel,
DINI: ConferencePaper,
DataCite: ConferencePaper
|
Verlag: |
Verlag:
Physikalisch-Technische Bundesanstalt (PTB)
|
Rechte: |
Rechte:
https://creativecommons.org/licenses/by/4.0/CC-BY 4.0 |
Beziehungen: |
Beziehungen:
IsIdenticalTo: DOI 10.1016/j.apradiso.2025.112204
|
Datumsangaben: |
Datumsangaben:
Verfügbar:
2025-10-01
Herausgegeben: 2025-12 |
Datei: |
Datei:
Datei herunterladen
(application/pdf)
1.2 MB
MD5 Prüfsumme: f1bacdf5bd05a1b68387d80188ede5d2 SHA256 Prüfsumme: 5f836ee17bc375c2a79fc523aa542d3653f202b4792ab20af06b7f7e89c2f540 |
Stichwörter: |
Stichwörter:
reference material ;
homogeneity ;
quality control ;
environmental monitoring
|
Zusammenfassung: |
Zusammenfassung:
There are very few radioactive environmental reference materials (RM) traceable to the International System of Units. Existing radioactive RMs for environmental samples that can be measured by mass spectrometry are even more limited and their characterisation does not always include relevant parameters such as isotopic ratios. This paper focuses on the development of two environmentally relevant candidate RMs, one liquid and one solid, which could be used for routine quality control measurements. The liquid RM was prepared by spiking seawater sampled from the North Sea, and therefore the matrix is representative of a real environmental sample, while the solid RM was prepared using a synthetic approach by spiking a mixture of silica precursors before a sol-gel reaction. The homogeneity, between-bottles and within-bottles, of both RMs was assessed using gamma-ray spectrometry and mass spectrometry. For the liquid RM, the variation among sub-samples was due mainly to the within-bottle variance, and was lower than 1 %, for all the radionuclides tested. For the solid RM, the 241Am content measured with gamma-ray spectrometry revealed a statistically significant variation between-bottles, but was lower than 1 %. The 238U and 239Pu contents, measured by mass spectrometry, showed higher measurement variability (~5 %), with the main contribution coming from within the bottles.
|
Bemerkung: |
Bemerkung:
Part of special issue 24th International Conference on Radionuclide Metrology and its applications (ICRM 2025)
|
Förderung: |
Förderung:
European Commission (EC), ISNI: 0000 0001 2162 673X, Grant Title: Metrology for the harmonisation of measurements of environmental pollutants in Europe, Grant Number: EPM 21GRD09 MetroPOEM
|

-OAR