Titel:
Titel:
Ex-Situ and Operando NEXAFS Spectra of Organo-Sulfur Compounds
Autoren:
Autoren:
Skudler, Konstantin, Physikalisch-Technische Bundesanstalt (PTB), Fachbereich 7.2, Röntgenmesstechnik mit Synchrotronstrahlung, ORCID: 0009-0003-3981-5709
Yang, Hongfei, Physikalisch-Technische Bundesanstalt (PTB), Fachbereich 7.2, Röntgenmesstechnik mit Synchrotronstrahlung, ORCID: 0009-0003-5146-2766
Matsidik, Rukiya, Technische Universität Chemnitz (TUC), Chemnitz, Germany, ORCID: 0000-0002-3535-1076
Müller, Matthias, Physikalisch-Technische Bundesanstalt (PTB), Fachbereich 7.2, Röntgenmesstechnik mit Synchrotronstrahlung, ORCID: 0000-0003-0115-7854
Beitragende:
Beitragende:
HostingInstitution: Physikalisch-Technische Bundesanstalt (PTB), ISNI: 0000 0001 2186 1887
Sprachen:
Sprachen:
en
DOI:
DOI:
10.7795/720.20250710
Art der Ressource:
Art der Ressource:
PTB: Messdaten, DINI: ResearchData, DataCite: Dataset
Verlag:
Verlag:
Physikalisch-Technische Bundesanstalt (PTB)
Rechte:
Rechte:
https://creativecommons.org/licenses/by/4.0/
CC-BY 4.0 International
Datumsangaben:
Datumsangaben:
Verfügbar: 2025-08-06
Klassifikationen:
Klassifikationen:
INSPEC A30 Atomic and molecular physics
Datei:
Datei:
Datei herunterladen (application/zip) 4.0 MB
MD5 Prüfsumme: 92931ffaedfea7b91341b479b585a6af
SHA256 Prüfsumme: 22ba515355722e56fc06c1e763f92cb0cfbd867035854ae4174f9f4b7a0b4ec3
Stichwörter:
Stichwörter:
X-ray spectrometry ; X-ray spectroscopy ; NEXAFS ; XAFS ; organo-sulfur ; sulfur strand length ; operando ; lithium-sulfur battery ; polymer battery
Zusammenfassung:
Zusammenfassung:
This dataset includes operando Near-Edge X-ray Absorption Fine Structure (NEXAFS) spectra of lithium organo-sulfur battery half-cells during Cyclic Voltammetry (CV), as well as ex-situ NEXAFS spectra of organo-sulfur compounds and polymer networks. All NEXAFS spectra were taken in fluorescence mode using energy-dispersive silicon drift detectors (SDD) in the PTB laboratory at BESSY II. The operando NEXAFS spectra of lithium organo-sulfur battery half-cells were taken at the Four Crystal Monochromator (FCM) beamline using Si (111) crystals with a fluorescence detection angle of 60 °. CV was performed with a BioLogic VSP potentiostat. The ex-situ NEXAFS spectra of organo-sulfur compounds and polymer networks were taken at the Tender X-ray MicroFocus (MiFo) beamline, operated in Double Crystal Monochromator (DCM) mode using Si (111) crystals with a fluorescence detection angle of 90 °. The file names include the measurement technique (CV or NEXAFS) followed by the sample name and, if applicable, further keywords like "powder" for powder samples or "operando" for operando measurements.
Förderung:
Förderung:
Deutsche Forschungsgemeinschaft (DFG), ISNI: 0000 0001 2096 9829, Grant Title: Priority Programme “Polymer-Based Batteries”, Grant Number: SPP 2248

Autoren

Skudler, Konstantin, Physikalisch-Technische Bundesanstalt (PTB), Fachbereich 7.2, Röntgenmesstechnik mit Synchrotronstrahlung, ORCID: 0009-0003-3981-5709
Yang, Hongfei, Physikalisch-Technische Bundesanstalt (PTB), Fachbereich 7.2, Röntgenmesstechnik mit Synchrotronstrahlung, ORCID: 0009-0003-5146-2766
Matsidik, Rukiya, Technische Universität Chemnitz (TUC), Chemnitz, Germany, ORCID: 0000-0002-3535-1076
Müller, Matthias, Physikalisch-Technische Bundesanstalt (PTB), Fachbereich 7.2, Röntgenmesstechnik mit Synchrotronstrahlung, ORCID: 0000-0003-0115-7854

PTB-OAR Menü

Sprache wechseln: uk flag