Title:
Title:
Equivalent Threshold Sound Pressure Levels (ETSPLs) for circumaural Sony WH-1000XM4 headphones
Authors:
Authors:
Bug, Marion U., Physikalisch-Technische Bundesanstalt, Fachbereich 1.6 Schall, ORCID: 0000-0003-4795-8438
Fedtke, Thomas, Physikalisch-Technische Bundesanstalt, Fachbereich 1.6 Schall
Contributors:
Contributors:
HostingInstitution: Physikalisch-Technische Bundesanstalt (PTB), ISNI: 0000 0001 2186 1887
Languages:
Languages:
en
DOI:
DOI:
10.7795/720.202412206
Resource Type:
Resource Type:
Dataset / Measurement Data
Publisher:
Publisher:
Physikalisch-Technische Bundesanstalt (PTB)
Rights:
Rights:
https://creativecommons.org/licenses/by/4.0/
CC-BY 4.0 International
Dates:
Dates:
Available: 2024-12-06
Classifications:
Classifications:
INSPEC B6450 Audio equipment and systems ; PACS 43.66.-x Hearing ; PACS 43.66.Cb Loudness, absolute threshold ; PACS 43.66.Yw Instruments and methods related to hearing and its measurement
File:
File:
Download File (application/zip) 2.50 kB (2556 Bytes)
MD5 Checksum: 446e575123b769b6e73f7bc26cc16f10
SHA256 Checksum: 2498638fdcbb1ddb63f1bd1c4d9e379e710a7ec28b75ad3dd053b820a6313401
Keywords:
Keywords:
Audiometry ; sound pressure level ; hearing threshold ; Sony WH-1000XM4
Abstract:
Abstract:
Headphone sensitivity levels and ETSPL values were determined for Sony WH-1000XM4 headphones and an ear simulator according to IEC 60318-1
Table of Contents:
Table of Contents:
- file: "Sensitivity levels Sony WH-1000XM4.dat"
research object: Sensitivity levels (dB re 1 Pa/V) of Sony WH-1000XM4 earphones for an ear simulator according to IEC 60318-1 with flat plate and conical ring (informative).
method: Six Sony WH-1000XM4 earphones were subsequently placed on the IEC 60318-1 ear simulator. Each earphone was placed horizontally and concentrically on the plate with its application force resulting from an ear-phone distance of 145 mm. The earphones were switched off and connected by stereo audio jacks.
format: dat
recommended software: Text Editor, Excel, etc.
parameters: "Frequency / Hz", "Mean sensitivity level / dB re 1 Pa/V", "Standard deviation / dB re 1 Pa/V"

- file: "ETSPL Sony WH-1000XM4.dat"
research object: Equivalent threshold sound pressure levels (ETSPLs) re 20 µPa for the headphone type Sony WH-1000XM4 and an ear simulator according to IEC 60318-1 with flat plate and conical ring
method: ETSPLs were determined according to ISO 389-9. The headphone was switched off and connected by stereo audio jacks
format: dat
recommended software: Text Editor, Excel, etc.
parameters: "Frequency / Hz", "Median value (ETSPL) / dB", "Mean value / dB", "Std. dev. / dB", "1st Quartile / dB", "3rd Quartile / dB", "Uncertainty (k=2) / dB"

Authors

Bug, Marion U., Physikalisch-Technische Bundesanstalt, Fachbereich 1.6 Schall, ORCID: 0000-0003-4795-8438
Fedtke, Thomas, Physikalisch-Technische Bundesanstalt, Fachbereich 1.6 Schall