Title: |
Title:
Additional data for the publication ‘Simple and compact diode laser system stabilized to Doppler-broadened iodine-lines at 633 nm’
|
Authors: |
Authors:
Krause, Florian, Physikalisch-Technische Bundesanstalt, Fachbereich 4.3, Quantenoptik und LängeneinheitBenkler, Erik, Physikalisch-Technische Bundesanstalt, Fachbereich 4.3, Quantenoptik und Längeneinheit, ORCID: 0000-0001-7907-849X Nölleke, Christian, OPTICA Photonics AG, Gräfelfing Leisching, Patrick, OPTICA Photonics AG, Gräfelfing Sterr, Uwe, Physikalisch-Technische Bundesanstalt, Fachbereich 4.3, Quantenoptik und Längeneinheit, ORCID: 0000-0001-5661-769X |
Contributors: |
Contributors:
HostingInstitution: Physikalisch-Technische Bundesanstalt (PTB), ISNI: 0000 0001 2186 1887
|
Languages: |
Languages:
en
|
DOI: |
DOI:
10.7795/720.20201111
|
Version: |
Version:
1
|
Resource Type: |
Resource Type:
Dataset / Measurement Data
|
Publisher: |
Publisher:
Physikalisch-Technische Bundesanstalt (PTB)
|
Rights: |
Rights:
https://creativecommons.org/licenses/by-nd/4.0/CC BY-ND 4.0 (Creative Commons Attribution-NoDerivatives 4.0 International Public License) |
Relationships: |
Relationships:
IsPartOf: DOI 10.1364/AO.409308
|
Dates: |
Dates:
Available: 2020-11-11 |
Classifications: |
Classifications:
INSPEC A4260B Design of specific laser systems ; INSPEC A0760L Optical interferometry ; INSPEC A3580 Atomic and molecular measurements and techniques
|
File: |
File:
Download File
(application/zip)
9.56 MB (10021717 Bytes)
MD5 Checksum: aa6bf7acb22f221be3ffdadc32892b93 SHA256 Checksum: f3693be78b065334f3fb3cae1b503fab713a307bb3111ff351078e5fac0ee0fe |
Keywords: |
Keywords:
Diode laser ;
Iodine spectroscopy ;
Absolute frequency measurement ;
Laser stability
|
Abstract: |
Abstract:
The data sets provide additional information on the experiments and the physical background discussed in the publication entitled ‘Simple and compact diode laser system stabilized to Doppler-broadened iodine-lines at 633 nm’ in Applied Optics (DOI: 10.1364/AO.409308).
Description of the individual files: The file 'Trans_spectrum.dat' provides the normalized iodine transmission data as a function of the laser diode temperature (shown in fig. 2). The file 'nu_R(74)_8-4.dat' provide a time series of the absolute frequency calculated of the measured frequency difference between the diode laser and the frequency comb (shown in fig 4). The data sets 'P(54)_6-3_mod_Adev.dat', 'R(59)_6-3_mod_Adev.dat', 'R(74)_8-4_mod_Adev.dat' and 'R(77)_8-4_mod_Adev.dat' provide the calculated modified Allan deviation of the laser system stabilized to four different Doppler-broadened iodine lines. (shown in fig. 6) |
Other: |
Other:
EMPIR projects are co-funded by the European Union’s (EU) Horizon 2020 research and innovation programme and the EMPIR participating states.
|
Citation: |
Citation:
Krause, Florian ; Benkler, Erik ; Nölleke, Christian ; et al. Additional data for the publication ‘Simple and compact diode laser system stabilized to Doppler-broadened iodine-lines at 633 nm’. Physikalisch-Technische Bundesanstalt (PTB). DOI: 10.7795/720.20201111
|
Funding: |
Funding:
European Commission (EC), ISNI: 0000 0001 2162 673X, Grant Title: Ultra-stable optical oscillators from quantum coherent and entangled systems, Grant Number: EMPIR 17FUN03 USOQSBundesministerium für Bildung und Forschung, ISNI: 0000 0001 2342 0436, Grant Title: Frequenzstabilisierte Diodenlaser der nächsten Generation für Metrologie und Life Science, Grant Number: FKZ 13N13954 FinDLiNG |

-OAR